Customization: | Available |
---|---|
Breaking Capacity: | High |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features :Strap devices, Axial leaded,Protection for NiCd/NiMH rechargeable battery packs, Li-ion /Polymer Li-ion battery,Available in lead-free version,Agency recognition: UL,CSA,TUV.
IH=Hold current: maximum current at which the device will not trip at 25ºC still air.
IT=Trip current: minimum current at which the device will always trip at 25ºC still air.
Vmax=Maximum voltage device can withstand without damage at rated current.
Imax=Maximum fault current device can withstand without damage at rated voltage.
Max Time-to-trip=Maximum time to trip(s) at assigned current.
Pd max=Maximum power dissipation: maximum power dissipated by the device when in state air environment.
Rmin=Minimum device resistance at 25ºC prior to tripping.
Rmax=Maximum device resistance at 25ºC prior to tripping.
R1max=Maximum device resistance at 25ºC, of device one hour after being tripped the first time.